8414 Air or vacuum pumps, air or other gas compressors and fans; ventilating or recycling hoods incorporating a fan; gas-tight biological safety cabinets whether or not fitted with filters
Combined Nomenclature and TARIC · MFN rates · Chapter 84, Machinery and mechanical appliances, boilers, nuclear reactors; parts thereof
CodeDescriptionMFN rate
8414.10 Pumps; vacuum
- 8414.10.15.00 Of a kind used for the manufacture of semiconductors or solely or principally used for the manufacture of flat panel displaysFree
- Other
- Rotary piston pumps, sliding vane rotary pumps, molecular drag pumps and Roots pumps
- 8414.10.25.10 For use in civil aircraft4.5%
- 8414.10.25.30 Tandem pump consisting of: an oil pump with displacement of 21,6 cc/rev (± 2 cc/rev) and working pressure 1,5 bar at 1 000 revolutions per minute; vacuum pump with displacement of 120 cc/rev (± 12 cc/rev) and performance of -666 mbar in 6 seconds at 750 revolutions per minute; for use in the manufacture of engines of motor vehicles1.7%
- 8414.10.25.90 Other1.7%
- Other
- Diffusion pumps, cryopumps and absorption pumps
- 8414.10.81.10 For use in civil aircraft4.5%
- 8414.10.81.90 Other1.7%
- Other
- 8414.10.89.10 For use in civil aircraft4.5%
- 8414.10.89.90 Other1.7%
8414.20 Pumps; hand or foot-operated air pumps
- 8414.20.20.00 Handpumps for cycles1.7%
- Other
- 8414.20.80.10 For use in civil aircraft4.5%
- 8414.20.80.90 Other2.2%
8414.30 Compressors; of a kind used in refrigerating equipment
- Of a power not exceeding 0,4 kW
- 8414.30.20.10 For use in civil aircraft4.5%
- 8414.30.20.60 Hermetic compressor for R290 refrigerant for the production of refrigerators and freezers: with a power not exceeding 0.4 kW; pre-filled with lubricant from 190 ml to 210 ml; suction and processing pipe inner diameter from 6.40 mm to 6.60 mm; discharge pipe inner diameter from 4.80 mm to 5.00 mm; driven by a brushless DC motor; cooling capacity from 340 to 360 W at ASHRAE LBP 3000 rpm; displacement from 6.5 cm³ to 7.5 cm³; speed range from 1,600 rpm to 4,200 rpm2.2%
- 8414.30.20.90 Other2.2%
- Of a power exceeding 0,4 kW
- Hermetic or semi-hermetic
- 8414.30.81.10 For use in civil aircraft4.5%
- Other
- 8414.30.81.50 Hermetic or semi-hermetic variable-speed electric scroll compressors, with a nominal power rating of 0,5 kW or more but not more than 10 kW, with a displacement volume of not more than 35 cm³, of the type used in refrigeration equipment2.2%
- 8414.30.81.60 Hermetic rotary compressors for either hydrofluorocarbon (HFC) or hydrocarbon refrigerants: driven by ‘on-off’ single phase alternate current (AC) or ‘brushless direct current’ (BLDC) variable speed motors; with a nominal power rating of not more than 1,5kW; a rated voltage of 100V or more but not more than 240V; with a height of not more than 300mm; an external diameter of not more than 150mm; with a unit weight of not more than 15kg; for use in the manufacture of heat pumps for household appliances, including clothes dryers2.2%
- 8414.30.81.89 Other2.2%
- Other
- 8414.30.89.10 For use in civil aircraft4.5%
- 8414.30.89.20 Vehicle air conditioning system part, consisting of an open shaft reciprocating compressor of a power of more than 0,4 kW but not more than 10 kW2.2%
- 8414.30.89.40 Electrical compressor for motor vehicle air conditioning system: with a power output of more than 0,4 kW but not exceeding 10 kW; for use in the manufacture of motor vehicles of subheading 8703 402.2%
- 8414.30.89.90 Other2.2%
8414.40 Compressors; air compressors mounted on a wheeled chassis for towing
- 8414.40.10.00 Giving a flow per minute not exceeding 2 m³2.2%
- 8414.40.90.00 Giving a flow per minute exceeding 2 m³2.2%
8414.51 Fans; table, floor, wall, window, ceiling or roof fans, with a self-contained electric motor of an output not exceeding 125W
- 8414.51.00.10 For use in civil aircraft4.5%
- 8414.51.00.90 Other3.2%
8414.59 Fans; n.e.c. in item no. 8414.51
- 8414.59.15.00 Fans of a kind used solely or principally for cooling microprocessors, telecommunication apparatus, automatic data processing machines or units of automatic data processing machinesFree
- Other
- Axial fans
- 8414.59.25.10 For use in civil aircraft4.5%
- 8414.59.25.50 Axial fans with built-in motor, for the generation of an air flow for the cooling of compressors and the distribution of air with: a direct current operating voltage of more than 10 V but not more than 14 V, or an alternating current operating voltage of more than 185 V, but not more than 254 V; an operating temperature of -40 °C or higher, but not higher than 70 °C; for use in the manufacture of heat pump tumble dryers and refrigerators or freezers2.3%
- 8414.59.25.60 Axial Fan, for incorporation into instrument clusters, speedometers and infotainment systems of transport vehicles as motor vehicles of headings 8701 to 8705, with: an air flow of not more than 0,75 m3/min (cubic meter per minute); an air pressure of not more than 10 mmH2O; an overall acoustic noise of not more than 45 dB(A); a diameter of not more than 65mm; Equipped with DC Brushless motor with: a rated voltage between: 3 to 16 VDC; an operating voltage between: 3 to 16 VDC; a rated current between: 0,03 to 0,30 A; an input power between: 0,3 to 1,5 W; a rotation speed between: 2500 to 10000 R.P.M; With or without a heat sink incorporated2.3%
- 8414.59.25.90 Other2.3%
- Centrifugal fans
- 8414.59.35.10 For use in civil aircraft4.5%
- 8414.59.35.20 Radial fan, with: a dimension of 25mm (height) x 85mm (width) x 85mm (depth); a weight of 120 g; a rated voltage of 13,6 VDC (direct current voltage); an operating voltage of 9 VDC or more but not more than 16 VDC (direct current voltage); a rated current of 1,1 A (TYP); a rated power of 15 W; a rotation speed of 500 RPM (revolutions per minute) or more but not more than 4800 RPM (revolutions per minute) (free flow); an air flow of not more than 17,5 litre/s; an air pressure of not more than16 mm H2O ≈ 157 Pa; an overall sound pressure of not more than 58 dB(A) at 4800 RPM (revolutions per minute), and with a FIN (Fan Interconnect Network) interface for communication with the heating and air-conditioning control unit used in car seat ventilation systems2.3%
- 8414.59.35.30 Electric blower for cooling the high-voltage battery of a hybrid passenger car with: a control unit; MOSFET inverter; a voltage of 9 V or more but not more than 16 V; ambient temperature of - 40 °C or more, but not more than 80 °C; for use in the manufacture of hybrid passenger cars2.3%
- 8414.59.35.40 Electric blower for cooling the battery module: with an operating voltage of 9 VDC or more but not more than 16 VDC; with a centrifugal electric fan; with a connector; with a plastic case; with or without a control unit for the fan electric motor; for use in the production of rechargeable batteries for hybrid and electric vehicles2.3%
- 8414.59.35.50 DC motor centrifugal fan with: a nominal voltage of 8 V or more, but not more than 13 V; a nominal maximum speed of 1400 rpm or more, but not more than 1950 rpm; a horizontal or vertical position of the fan blades shaft; a boosting time of not more than 10 seconds; a cable with a length of 30 cm or more, but not more than 50 cm, with RAST 2,5 connector; a nominal power of 0,7 W or more, but not more than 3,5 W; a tacho or feedback signal to monitor the speed2.3%
- 8414.59.35.90 Other2.3%
- Other
- 8414.59.95.10 For use in civil aircraft4.5%
- 8414.59.95.90 Other2.3%
8414.60 Hoods; ventilating or recycling hoods incorporating a fan, whether or not fitted with filters, having a maximum horizontal side not exceeding 120cm
- 8414.60.00.00 Hoods having a maximum horizontal side not exceeding 120 cm2.7%
8414.70 Gas-tight biological safety cabinets; whether or not fitted with filters, having a maximum horizontal side not exceeding 120cm
- 8414.70.00.00 Gas-tight biological safety cabinets2.2%
8414.80 Pumps and compressors; for air, vacuum or gas, n.e.c. in heading no. 8414
- Turbo-compressors
- Single-stage
- 8414.80.11.10 For use in civil aircraft4.5%
- 8414.80.11.90 Other2.2%
- Multi-stage
- 8414.80.19.10 For use in civil aircraft4.5%
- 8414.80.19.90 Other2.2%
- Reciprocating displacement compressors, having a gauge pressure capacity of
- Not exceeding 15 bar, giving a flow per hour
- Not exceeding 60 m³
- 8414.80.22.10 For use in civil aircraft4.5%
- 8414.80.22.20 Air membrane compressor with: a flow of 4,5 l/min or more, but not more than 12 l/min; power input of not more than 14 W, and a gauge pressure capacity not exceeding 400 hPa (0,4 bar); of a kind used in the production of motor vehicle seats2.2%
- 8414.80.22.90 Other2.2%
- Exceeding 60 m³
- 8414.80.28.10 For use in civil aircraft4.5%
- 8414.80.28.90 Other2.2%
- Exceeding 15 bar, giving a flow per hour
- Not exceeding 120 m³
- 8414.80.51.10 For use in civil aircraft4.5%
- 8414.80.51.90 Other2.2%
- Exceeding 120 m³
- 8414.80.59.10 For use in civil aircraft4.5%
- 8414.80.59.90 Other2.2%
- Rotary displacement compressors
- Single-shaft
- 8414.80.73.10 For use in civil aircraft4.5%
- Other
- 8414.80.73.30 Hermetic rotary compressors for either hydrofluorocarbon (HFC) or hydrocarbon refrigerants: driven by ‘on-off’ single phase alternate current (AC) or ‘brushless direct current’ (BLDC) variable speed motors; with a nominal power rating of not more than 1,5kW; a rated voltage of 100V or more but not more than 240V; with a height of not more than 300mm; an external diameter of not more than 150mm; with a unit weight of not more than 15kg; for use in the manufacture of heat pumps for household appliances, including clothes dryers2.2%
- 8414.80.73.50 Hermetic heat pump compressor for R450A or R290 refrigerants: not charged with refrigerant; pre-charged with lubricant oil; with a single phase induction permanent split capacitor motor or a DC brushless motor; having suction and/or discharge connections; with a displacement of 8,05 cm3 or more, but not more than 55 cm3; running at 900 rpm or more, but not more than 7 800 rpm, and with a cooling capacity of 920 W or more, but not more than 10 440 W in ASHRAE conditions2.2%
- 8414.80.73.89 Other2.2%
- Multi-shaft
- Screw compressors
- 8414.80.75.10 For use in civil aircraft4.5%
- 8414.80.75.90 Other2.2%
- Other
- 8414.80.78.10 For use in civil aircraft4.5%
- 8414.80.78.90 Other2.2%
- Other
- 8414.80.80.10 For use in civil aircraft4.5%
- 8414.80.80.90 Other2.2%
8414.90 Pumps and compressors; parts, of air or vacuum pumps, air or other gas compressors and fans, ventilating or recycling hoods incorporating a fan
- 8414.90.00.10 For use in civil aircraft4.5%
- 8414.90.00.15 Fan assembly made of aluminium and magnesium alloy: with an outer diameter of 54 mm or more but not more than 130 mm; with a height of 8 mm or more but not more than 30 mm; with two discs connected by blades of involute shape; with or without dowel, and with or without washer; for use in the manufacture of electromotors2.2%
- 8414.90.00.20 Aluminium pistons, for incorporation into compressors of air conditioning machines of motor vehicles2.2%
- 8414.90.00.25 Scroll type compressor housing of an aluminium alloy of a kind with: a heat resistance of 200 °C or more but not more than 250 °C; one or more fixing points suitable for mounting an actuator; for use in the manufacture of turbochargers2.2%
- 8414.90.00.35 Compressor head unit made of impregnated aluminium alloy for installation in air-conditioning compressors for motor vehicles with: a width of 115 mm or more but not more than 160 mm; a length of 115 mm or more but not more than 170 mm; a height of 30 mm or more but not more than 100 mm; a piece of pressure branch with pipe connection; one or two mounting holes and more than one overflowing hole2.2%
- 8414.90.00.45 Pressure casted rotor front plate or cover of an electric supercharger: of EN AC-46000 aluminium; shot-blasted and machined; with a hardness of 60 or more on the Hardness Brinell Wolfram (HBW) scale (2,5/62,5, according to ISO 6506); with a tensile strength of 240 N/mm2 or more; with a height of 22 mm or more but not more than 26 mm; with a diameter of 128 mm or more but not more than 136 mm; with a weight of 220 g or more but not more than 250 g2.2%
- 8414.90.00.55 Air conditioning compressor housing component made of aluminum alloy for installation in electric air conditioning compressors for motor vehicles: with a width of 100 mm or more but not more than 220 mm; with a length of 100 mm or more but not more than 230 mm; with a height of 80 mm or more but not more than 180 mm; with one single central bore; machined by CNC milling or unwrought; whether or not impregnated; with one suction port or without2.2%
- 8414.90.00.80 Turbocharger wheel housing of cast aluminium alloy or cast iron: with a heat resistance up to 400°C; with a hole of 30 mm or more but not more than 300 mm for the insertion of the compressor wheel; for use in the automotive industry2.2%
- 8414.90.00.90 Other2.2%
MFN rates from the Combined Nomenclature and TARIC as published, without preferences, quotas, trade remedies or additional measures. Inferred works those out for each product and origin. Whether a product from this heading qualifies for a lower rate depends on each agreement's product-specific rule for it, under the agreements we cover.
Every line in chapter 84